HOME > Product Information > Deodorization Equipment, Exhaust Treatment > Heat Reserved Catalytic Combustion Type Deodorization Equipment
Heat Reserved Catalytic Combustion Type Deodorization Equipment

Features

- Low-temperature decomposition by Pt catalytic combustion and thermal storage medium (Exhaust heat recovery rate 95% or higher) created this energy-saving environment-friendly (low CO2 emission) product.
- Air slide damper which instantly changes the direction of treating gas flow has a simple structure and excellent durability.
- Heat source employs an electric sheath heater which is easy to control and maintain.
- Standard equipment includes a sequencer that enables automatic operation and a touch panel which has excellent visibility. In an emergency, status and handling procedure are displayed as a telop. It is possible to copy operation data using USB port.
- Multiple temperature sensors are equipped at each booth. At the time of over-heating, safe operation program initiates stage control system.

Touch panel (with built-in sequencer)

Usage

- Low-concentrated (up to 1000ppmC level) VOC emission treatment of middle-level air volume up to 100m3/min
- Suitable for users seeking for low running energy cost, low NOx and low CO2 emission
- Users who wants to use electricity as power source

Main specifications

PST model Model PST-25 PST-50 PST-75 PST-100
Processing air volume m3/min 25 50 75 100
Device dimension
(mm)
W 2200 2600 3300 4000
D 1500 2300 2300 2300
H 1800 1800 2500 3000
Heater capacity kw 25 50 75 100
Blower capacity (inverter) kw 5.5 7.5 11 18.5

- This is non-explosion proof indoor installation type. (Rain cover is available.) Please consult us for an outdoor installation model.
- Control panel and exhaustion blower (soundproofed box) are separately attached for models PST-50 or higher.
- For emergency use, an exhaustion fan and a switch damper are additionally required for separate exhaustion from a source. (Consultation is available.)

※Please contact and consult us for detailed specifications.

●Important notification regarding equipment selection and installation
1) This equipment shall not be used to process substance containing catalyst poisoning gas (halogen compound, sulfur compound, phosphor compound,
   organosilocon and heavy metal compound), high boiling substances, tar mist, highly-humid gas, gas with dust or mist, acid gas and highly concentrated gas
   with high risk of explosion.
2) Compressed air (0.4MPa) is required to drive a slide damper.
3) Please consult us if you have concern about the influence from suction force fluctuation (at the change of direction of gas flow).

Go to Top