HOME > Product Information > Heating Furnaces and Dryers > Explosion-proof Dryer (Electric Heater Heating System)
Explosion-proof Dryer
Air purged control panel prevents the penetration of explosive atmosphere such as solvent.

Air purged control panel prevents the penetration of explosive atmosphere such as solvent.
Safety performance is assured with the adoption of highly controllable electric heater heating system and an explosion vent.
Electric components that are not stored in a control panel including a motor, a temperature sensor, a switch, connectors and wiring are explosion-proof.

Explosion-proof dryer/Air-purged model

Model SKE-202 SKE-203 SKE-204 SKE-252 SKE-253 SKE-254
System Forced hot air circulating system
Temperature range ~200℃ ~250℃
Heat-up time 60 minutes to reach 200℃ from room temperature 75 minutes to reach 250℃ from room temperature
Dimension Inside dimension □600 □800 □1000 □600 □800 □1000
Material Exterior finish Bonderizing sheet baking finish (Ivory)
Interior finish SUS304 2B
Heating apparatus
(Fin sheath heater)
4.5KW 7.5KW 12KW 4.5KW 7.5KW 12KW
Air purged terminal box, Built-in overheat sensor for heater room
Circulation fan linear motor 0.4KW 0.75KW 0.75KW×2 pieces 0.4KW 0.75KW 0.75KW×2 pieces
Stored in air purged segment (with inverter) Explosion-proof motor, Main shaft cooling fan
Control panel Air purged * Emergency stop by blocking air
Instrumentation Program temperature controller, overheat protectors (2 lotions), JISK thermocouple (explosion-proof)
Purged air control Air flowmeter, needle valve, pressure detection software
Explosion vent Safety cover duct, Operation sensor LSW (explosion-proof)
Accessories Moving frame and adjusting bolts (Only for 202 and 252)

※Please contact and consult us for detailed specifications.
※Please ask us about 300℃ Heat-resistant Model (option), Oddly-shaped Work Handling Model and Oversized Material Model.
※Compressed air (0.2MPa) is required for air purge.

One-way Ventilation Model and Emergency Exhaustion Device Model

We produce One-way Ventilation Model which does not circulate hot air, and Emergency Exhaustion Device Model.

One-way Ventilation Model

One-way Ventilation Model

Emergency Exhaustion Device Model

Emergency Exhaustion Device Model